Features:
by Lineage Power
www.LineagePower.com
Lineage Power Lineage Power Lineage Power (China)
3000 Skyline Dr. 2841 Dow Avenue 1353 Chenqiao Road, Shanghai Sengpu Industrial Park
Mesquite, TX 75149 Tustin, CA 92780 USA Shanghai, 201401 China
Phone: (972) 284-2000 Phone: (714) 544-6665 Phone: 021 6710 8910
75 Watt Modular Power Supply
Universal AC Input Range (90-264 VAC)
Optional Power Factor Correction (CCH Models)
Low Prole for 1U High Applications
Meets VDE/FCC Class “B” EMI
Industry Standard 3 x 5” Footprint
Total Power Overload Limit Protection
Over-Current Protection
International Safety Certications - UL, CSA, TUV & CE Mark (LVD)
KEY MARKET SEGMENTS & APPLICATIONS
Automation Equipment Test Equipment
Industrial Applications POS Equipment
Computer Peripherals Gaming
Networking / Datacom
SPECIFICATIONS 75 Wat Switching Power Supply
Input Voltage Range Universal AC Input Range (90-264 VAC, 47-63 Hz
Input Current Maximum 1.25A (max continuous, 85VAC Full Load)
Inrush Current 20A @ 115 VAC / 32A @ 230 VAC (typical)
Input Protection Single fuse (2.0 or 3.5A / 250VAC / HB Type)
Power Factor Passive PFC for EN61000-3-2 Class D Compliance
Eciency 70% typical (65% minimum) @ 115 VAC (measured at full load)
EMI FCC and VDE Level “B” (Conducted)
Output Power 75 Watts Continuous
Over-Power Limit Set at 90W typical by sensing the primary input current
Over-Load Protection V1 & V2 of CCH74 Models / V1 of CCH75 Models only. 110 - 135% of max Iout. Output recovers when fault is removed
Over-Voltage Protection V1 & V2 of CCH74Models / V1 of CCH75Models only. Trip point set at 116%- 130%of V1 or V2. To reset, cycle input power
Voltage Adjustment Range ±5% of V1 only, V2 / V3 is xed
Regulation ±2% max of V1, V2 / V3 is ±5% max
Ripple & Noise 1% pk-pk maximum @ 20MHz
Operating Temperature Full load from 0 to 50ºC. Derates linearly from 50ºC to 70ºC at 2.5% per ºC, 8 CFM Required for Full Power
Shock & Vibration Per MIL STD-810E per 516.4 Part IV
Dimensions 3.00 x 5.00 x 1.95” (76.2mm x 125.7mm x 38.1mm) for standard open frame model
Safety Approvals UL 1950, CSA 22.2 No. 950 & 234, TUV (EN60950), CE Mark & CB Report
FEATURES BENEFITS
PFC Compliant to EN61000-3-2
Supports global use of power supply
Input Protection per EN61000-4 Designed to operate in harsh environmental conditions
Economical Lowered system costs
Flexibility With Options Custom capability without NRE & long lead-times
CCH Series
75 Watt Swithing Power Supply
rev 091201
MODEL
V1 OUTPUT V2 OUTPUT V3 OUTPUT
Vout Io Min Io Max Io Peak Vout Io Min Io Max Io Peak Vout Io Min Io Max Io Peak
CCH75F1 12 0 .60 6.25 8.00
CCH74C3 +3.3 0.60 9.00 10.00 +5.1 0.40 N/S 3.50 +5 0.10 1.00 N/S
CCH74D3 +3.3 0.90 9.00 10.00 +5.1 0.20 N/S 2.00 +12 0.10 1.00 N/S
CCH74H3 +5.1 0.90 9.00 10.00 +3.3 0.20 N/S 3.50 +12 0.10 1.00 N/S
CCH75K3 +5.1 0.90 9.00 10.00 +12 0.30 3.00 3.50 -12 0.10 1.00 1.50
CCH75Q3 +5.1 0.90 9.00 10.00 +15 0.30 3.00 3.50 -15 0.10 1.00 1.50