Data Sheet
September 10, 2013
Austin Lynx
TM
SMT Non-isolated Power Modules:
3.0 – 5.5Vdc Input; 0.75Vdc to 3.63Vdc Output; 10A output current
LINEAGE POWER 14
Thermal Considerations
The power modules operate in a variety of thermal
environments; however, sufficient cooling should always
be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up
is shown in Figure 34. Note that the airflow is parallel to
the long axis of the module as shown in figure 33. The
derating data applies to airflow in either direction of the
module’s long axis.
Air Flow
T
ref
To
p
View
Bottom View
Figure 33. T
ref
Temperature measurement location.
The thermal reference point, T
ref
used in the
specifications is shown in Figure 33. For reliable
operation this temperature should not exceed 115
o
C.
The output power of the module should not exceed the
rated power of the module (Vo,set x Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
Figure 34. Thermal Test Set-up.
Heat Transfer via Convection
Increased airflow over the module enhances the heat
transfer via convection. Thermal derating curves
showing the maximum output current that can be
delivered at different local ambient temperature (T
A
) for
airflow conditions ranging from natural convection and
up to 2m/s (400 ft./min) are shown in the Characteristics
Curves section.
A
ir
flow
x
Po w e r M o d u le
W
ind Tunnel
PWBs
8.3_
(0.325)
76.2_
(3.0)
Probe Location
for measuring
airflow and
ambient
temperature
25.4_
(1.0)