GE Consumer & Industrial
Electrical Distribution
AF-600 FP
TM
Apogee/FLN
Operating Instructions
The instructions do not purport to cover all details or variations in equipment nor to provide for every possible
contingency to be met in connection with installation, operation or maintenance. Should further information be
desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the
matter should be referred to the GE company.
AF-600 FP is a trademark of the General Electric Company.
GE Consumer & Industrial
41 Woodford Avenue
Plainville, CT 06062
www.geelectrical.com/drives
130R0461
*MG12Q102*
DET-629
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - Apogee/FLN

GE Consumer & IndustrialElectrical DistributionAF-600 FPTMApogee/FLNOperating InstructionsThe instructions do not purport to cover all details or

Page 2

The PID controller in the drive supports two feedback values and two setpoints. The feedback can be received in the form of network bus signals and/or

Page 3

AF-600 FP Apogee FLN Operating Instructions103

Page 4 - 1Introduction

3 Drive Network StrategiesThe drive has its own internal PID closed loop controller. This can be turned on or off, depending on the requirements of th

Page 5

28 CMD COAST In most cases, it is necessary to set this point to [NO] to make the drive run. If this is set to [COAST] while thedrive is running, the

Page 6 - 1.2.6 HP/kW Conversion

Network inputs to the frequency converter:In addition to start/stop control, which was discussed in Strategy Two, the FLN provides the frequency conve

Page 7

AF-600 FP Apogee FLN Operating Instructions144

Page 8 - 2 Drive Functional Features

4 Drive Special Functions4.1.1 Special FunctionsIn addition to the control strategies described above, the drive provides additional control flexibili

Page 9

AF-600 FP Apogee FLN Operating Instructions165

Page 10

5Network Connection5.1.1 Network ConnectionConnect the frequency converter to the RS-485 network as follows (see also diagram):1. Connect signal wires

Page 11

AF-600 FP Apogee FLN Operating Instructions186

Page 12 - 3 Drive Network Strategies

Contents1 Introduction3Safety 3Introduction 4About this Manual 4Assumptions 4HP/kW Conversion 52 Drive Functional Features7Drive Operation (F-64) 7Mot

Page 13 - 3.1.4 Strategy Four

6 Parameters6.1.1 Parameter SettingsThe frequency converter has a unique FLN address, which is transmitted over the RS-485 serial bus. The network wil

Page 14

AF-600 FP Apogee FLN Operating Instructions207

Page 15

7 Start-up and Troubleshooting7.1 Start-up7.1.1 Start-up of FLN ControlThis procedure assumes that the frequency converter has been installed properly

Page 16 - 4 Drive Special Functions

1. By using the [RESET] control button on the Keypad.2. Via a digital input with the “Reset” function.3. Via serial communication/optional network.4.

Page 17

No. Description Warning Alarm/Trip Alarm/Trip Lock Parameter Reference1 10 Volts low X 2 Live zero error (X) (X) par. AN-01 Live Zero Time-out

Page 18 - 5Network Connection

No. Description Warning Alarm/Trip Alarm/Trip Lock Parameter Reference200 Fire Mode X FB-0#201 Fire Mode was Active X K-7#202 Fire Mode Limits

Page 19

Pointno.6000pointno.DescriptorFactorydefault(SI)Engr.Unit(SI)Slope(SI)Intercept(SI)OntextOfftextRangeMaxvaue(SI)Minvalue(SI)PointtypeClassType(Note 1)

Page 20 - 6 Parameters

Pointno.6000pointno.DescriptorFactorydefault(SI)Engr.Unit(SI)Slope(SI)Intercept(SI)OntextOfftextRangeMaxvaue(SI)Minvalue(SI)PointtypeClassTypeReadOnly

Page 21

Pointno.6000pointno.DescriptorFactorydefault(SI)Engr.Unit(SI)Slope(SI)Intercept(SI)OntextOfftextRangeMaxvaue(SI)Minvalue(SI)PointtypeClassTypeReadOnly

Page 22 - 7.1 Start-up

Pointno.6000pointno.DescriptorFactorydefault(SI)Engr.Unit(SI)Slope(SI)Intercept(SI)OntextOfftextRangeMaxvaue(SI)Minvalue(SI)PointtypeClassTypeReadOnly

Page 23

6 Parameters19Parameter Settings 197 Start-up and Troubleshooting21Start-up 21Start-up of FLN Control 21Troubleshooting 21Faults, Warnings and Alarms

Page 24

Pointno.6000pointno.DescriptorFactorydefault(SI)Engr.Unit(SI)Slope(SI)Intercept(SI)OntextOfftextRangeMaxvaue(SI)Minvalue(SI)PointtypeClassTypeReadOnly

Page 25

7.3 Start-up7.3.1 Start-up of FLN ControlThis procedure assumes that the frequency converter has been installed properly and is operational in Hand co

Page 26 - 7.2.3 Point Mapping Table

GE Consumer & IndustrialElectrical DistributionAF-600 FPTMApogee/FLNOperating InstructionsThe instructions do not purport to cover all details or

Page 27

1Introduction1.1.1 SafetyRotating shafts and electrical equipment can be hazardous. Therefore, it is strongly recommended that all electrical work con

Page 28

1.2.1 IntroductionThe Siemens Floor Level Network (FLN) is a master/ slave control network for serial communication with various control devices. The

Page 29

1.2.5 Abbreviations and Standards Abbreviations: Terms: SI-units: I-P units:a Accelerationm/s2ft/s2AWG American wire gauge Auto Tune Automatic Moto

Page 30

AF-600 FP Apogee FLN Operating Instructions62

Page 31 - 7.3 Start-up

2 Drive Functional FeaturesThe FLN protocol built into the drive frequency converter allows programming of numerous features and monitoring of the dri

Page 32

2.1.8 Freeze Mode (25, 26)If desired, the frequency of the drive can be frozen at its present value. The mode is indicated by data point 25. It is an