Vue de la page 43
CH. 8: INSTALLATION 23 SEP 1999 PAGE 45
8.2.7 Re-assembly
a. Mount the regulator card with the GEN250 attached on the four standoffs with four screws. (See
Figure 8.4.)
b. Reconnect the ribbon cable between the lower power card and the regulation card. (See Figure 8.2.)
c. Replace the housing by sliding the housing tabs into the recess and slide downward until the points at
the lower end are engaged over pins.
d. Reconnect the four plugs that were removed during disassembly. Connect the two wires from the
GEN250 to points #18 and #19 (Figure 8.5).
SNAP TWO STANDOFFS
INTO REGULATION CARD
ATTACHMENT OF PCB TO REGULATION CARD
INSTALL POWER CABLE
INTO TERMINAL 18 & 19
STEP 2
INSTALL TWO
SCREWS
INSTALL JUMPER CABLE
19
18
Figure 8.3 – Installing GEN250
Figure 8.4 – Installing GEN250
STANDOFFS INTO BOARD
SNAP TWO PLASTIC
STEP 1
SCREW TWO STANDOFFS
INTO BOARD
J3
Vue de la page 43